| Electrical Characteristics |
| AC Input Voltage |
90-264VAC |
| Current Limit |
Set at 110%-150% |
| Efficiency |
80% Typical |
| Hold-up Time |
18mS (Full Load, 110VAC) |
| Input Current (High Line) |
0.8A |
| Input Current (Low Line) |
1.6A |
| Input Frequency |
47-63Hz |
| Inrush Current (High Line) |
21A Typical |
| Inrush Current (Low Line) |
15A Typical |
| Line Regulation |
0.5% Typical |
| Load Regulation |
3A Typical |
| Output Power Range |
120 Watts Max. |
| OVP |
Set at 112%-132% |
| Power Factor Correction |
0.97 Typical |
| Ripple and Noise (pk-pk) |
1% Typical |
| Start-up Time |
1 sec. Typical |
| Temperature Coefficient |
0.04%/deg. C |
| Transient Response |
4mS (Full Load to Half Load) |
| |
| Enviromental |
| Operating Temperature |
0 deg. C to 50 deg C Convection Cooled. Derate linearly to 50% at 70 deg. C |
| Relative Humidity |
5%-95% |
| Storage Temperature |
-40 deg C to +85 deg. C |
| |
| Safety Specifications |
| Dielectric Withstand Voltage (Primary to Ground) |
2121Vdc min. |
| Dielectric Withstand Voltage (Primary to Secondary) |
4242Vdc min. |
| EMI CISPR-11 |
Class B |
| EMI FCC Part-18 |
Class B |
| Isolation Resistance |
50M ohms |
| |